Ex Emergency Light BC9306AS, BC9306BS
Categories: EX Proof Lighting, Explosion Proof Emergency Lights
Model: BC9306AS, BC9306BS
IP Code: IP66
Ex Code: Ex d IIC T5/ T6 Gb
Ex tD A21 T95℃/ T80℃ Db
Ambient temp.: – 25℃ to +50℃
Standard: GB3836.1, GB3836.2
IEC60079-1:2007,MOD
ATEX Cert NO.: EPT16 ATEX 2484 X
IECEX Cert NO.: IECEx EUT 17.0011X
TORMIN is a manufacturer and trading company combined, including a whole Tech team to provide R&D and technical support. We are welcome your inquiry.
Product Details
Application
- Widely used in oil exploration, refining, chemical, military and other hazardous environments and offshore oil platforms to do general lighting and work lighting.
- Applicable to energy-saving renovation projects and places where maintenance and replacement are difficult;
- The explosion proof lighting fixtures are suitable for places with high protection requirements and humidity;
- Explosion proof LED flood light is applicable to areas 1 and 2 of the explosive gas environment;
- Is used in the IIC explosive gas environment;
- It is used for the temperature group of T3~T5 group;
Characteristics
- Tempered glass lens + special aluminum alloy shell, thickened glass, anti-scratch, anti-pressure, anti-drop, good light transmission
- High IP66 protection
- Dust-free electrostatic spraying process, fine spraying, anti-corrosion, waterproof and dustproof, bright and trustworthy
- Symmetrical heat sink for fast heat dissipation to prevent high heat aging
- Independent junction box, multiple inlets for easy installation and maintenance, saving junction box costs
- Type A: Usually used for 24-hour lighting fixtures to provide emergency lighting in the event of an accident; Type B: Accidental emergency lighting.
- Both Type A and Type B have manual emergency functions.
Main Specification
| Item | Technical Parameters |
| Type | BC9306AS/ BC9306BS |
| Rated voltage | 100~240VAC |
| Input frequency | 50Hz/ 60Hz |
| Light source | LED |
| CRI | Ra 70(80 Optional) |
| Service life | 50,000h |
| CCT | 5000K(3000K/4000K Optional) |
| Time of charging | >6h |
| Rated Capacity | 2.6Ah/ 14.8V |
| Screw Thread | G3/4″, NPT3/4″, M25, M20, NPT1/2″ |
| Leading-in cable diameter | Φ6mm~φ12mm |
| Terminals | Multi-core wire:≤2.5mm2 |
| Single-core wire:≤4mm2 | |
| Dimension | 245*260* 270mm |
| Net weight | 4.9 Kg |
Ordering Reference
|
Ordering |
Wattage |
Emergency wattage |
Emergency light output |
Emergency duration |
Space |
Equivalent to |
|
MH |
||||||
|
BC9306AS-L40-15 |
40W |
15W |
1800 lm |
120min |
1.25/1.75 |
100W/ 35W |
|
BC9306AS-L40-25 |
40W |
25W |
3300 lm |
70 min |
100W/ 70W |
|
|
Auto Emergency |
||||||
|
BC9306BS-L15 |
/ |
15W |
1800 lm |
120 min |
1.75 |
/ 35W |
|
BC9306BS-L25 |
/ |
25W |
3300 lm |
70 min |
/ 70W |
|
Production Details