Adriaan Roland Holststraat 33, Rotterdam

Ex Emergency Light BC9306AS, BC9306BS

Model: BC9306AS, BC9306BS
IP Code: IP66
Ex Code: Ex d IIC T5/ T6 Gb
Ex tD A21 T95℃/ T80℃ Db
Ambient temp.: – 25℃ to +50℃
Standard: GB3836.1, GB3836.2
IEC60079-1:2007,MOD
ATEX Cert NO.: EPT16 ATEX 2484 X
IECEX Cert NO.: IECEx EUT 17.0011X

TORMIN is a manufacturer and trading company combined, including a whole Tech team to provide R&D and technical support. We are welcome your inquiry.

Product Details


Application

  • Widely used in oil exploration, refining, chemical, military and other hazardous environments and offshore oil platforms to do general lighting and work lighting.
  • Applicable to energy-saving renovation projects and places where maintenance and replacement are difficult;
  • The explosion proof lighting fixtures are suitable for places with high protection requirements and humidity;
  • Explosion proof LED flood light is applicable to areas 1 and 2 of the explosive gas environment;
  • Is used in the IIC explosive gas environment;
  • It is used for the temperature group of T3~T5 group;

Characteristics

  • Tempered glass lens + special aluminum alloy shell, thickened glass, anti-scratch, anti-pressure, anti-drop, good light transmission
  • High IP66 protection
  • Dust-free electrostatic spraying process, fine spraying, anti-corrosion, waterproof and dustproof, bright and trustworthy
  • Symmetrical heat sink for fast heat dissipation to prevent high heat aging
  • Independent junction box, multiple inlets for easy installation and maintenance, saving junction box costs
  • Type A: Usually used for 24-hour lighting fixtures to provide emergency lighting in the event of an accident; Type B: Accidental emergency lighting.
  • Both Type A and Type B have manual emergency functions.

Main Specification

Item Technical Parameters
Type BC9306AS/ BC9306BS
Rated voltage 100~240VAC
Input frequency 50Hz/ 60Hz
Light source LED
CRI Ra 70(80 Optional)
Service life 50,000h
CCT 5000K(3000K/4000K Optional)
Time of charging >6h
Rated Capacity 2.6Ah/ 14.8V
Screw Thread G3/4″, NPT3/4″, M25, M20, NPT1/2″
Leading-in cable diameter Φ6mm~φ12mm
Terminals Multi-core wire:≤2.5mm2
Single-core wire:≤4mm2
Dimension 245*260* 270mm
Net weight 4.9 Kg


Ordering Reference

Ordering
reference

Wattage

Emergency wattage

Emergency light output

Emergency duration

Space
height
ratio

Equivalent to

MH

BC9306AS-L40-15

40W

15W

1800 lm

120min

1.25/1.75

100W/ 35W

BC9306AS-L40-25

40W

25W

3300 lm

70 min

100W/ 70W

Auto Emergency

BC9306BS-L15

/

15W

1800 lm

120 min

1.75

/ 35W

BC9306BS-L25

/

25W

3300 lm

70 min

/ 70W

 

 